We strive to mitigate a wide range of the environmental burden, by grasping total GHG emissions from upstream through downstream and reducing them.

Unit: tons-CO2

ItemsFY2018FY2019FY2020FY2021FY2022FY2023
Scope 3
(Upstream)
CAT 01Purchased goods and services 139,263104,240100,628121,440137,495145,321
CAT 02Capital goods1338000122323
CAT 03Fuel and energy-related activities not included in Scopes 1 and 26011,2541,2181,1271,001943
CAT 04Transportation and distribution (Upstream)2,7692,1331,6512,1012,8351,963
CAT 05Waste generated in operations202150127123138153
CAT 06Business travel1,5122,8074754248781,279
CAT 07Employee commuting1,094942821048996
CAT 08Leased assets (Upstream)726656586516521560
Scope 1 (Reporting company)Direct Emissions5815341,0861,0951,1521,020
Scope 2 (Reporting company)*1Indirect emissions from energy sourcesLocation-based11,0559,6258,2777,4886,3246,061
Market-based10,6379,2047,8437,4376,0915,867
Scope 3
(Downstream)
CAT 09Transportation and distribution (Downstream)N/A *2N/AN/AN/AN/AN/A
CAT 10Processing of sold products- *2-----
CAT 11Use of sold products110,90268,04274,07195,61393,08698,862
CAT 12End-of-life treatment of sold productsN/AN/AN/A1,4231,3681,428
CAT 13Leased assets (Downstream)N/AN/AN/AN/AN/AN/A
CAT 14FranchisesN/AN/AN/AN/AN/AN/A
CAT 15InvestmentsN/AN/AN/AN/AN/AN/A
Total emissions in Scope 3 (CAT 01 - 15)257,082180,604178,838222,871237,532250,928
Total emissions in Scope 1 - 3 (Scope 2 is location-based)268,718190,763188,201231,454245,008258,009
  • *1:
    GWP (global-warming potential) of "Location-based" is all "0.57 tons-CO2/MWh". GWPs of "Market-based" are mainly based on data provided by each local electric power company in the territories where our Group Sites are located. The GWPs exclude electricity as RE.
  • *2:
    "N/A" means items which we regarded as not applicable to our Group. "-" means item which was decided not to calculate because it is practically difficult to calculate and its assumed emission volume is relatively small, although the CAT is applicable to our Group.

[Supplements] About calculations of each CAT in Scope 3

 CATsScopeCalculation MethodsSources
01Purchased goods and servicesIn JapanComponents purchased during the fiscal year x Emissions per unit of purchaseEmbodied Energy and Emissions Intensity Data (3EID) published by the National Institute for Environmental Studies Center for Global Environmental Research
02Capital goodsIn JapanTotal amounts of acceptance inspection of construction objects in the fiscal year x Emission intensityDatabase of emissions unit values published by Ministry of the Environment and Ministry of Economy, Trade and Industry
03Fuel and energy-related activities not included in Scopes 1 and 2Main 5 Sites*3Annual amounts of fuel oil and gas, electricity and heat purchased (consumed) at mainly business sites owned by Fujitsu Frontech Group x Emissions per unitDatabase of emissions unit values published by Ministry of the Environment and Ministry of Economy, Trade and Industry
04Transportation and distribution (Upstream)- Niigata Plant
(in Japan)
- FFNA
(outside Japan)
In Japan: CO2 emissions related to transportation of goods in Japan by Fujitsu Frontech Limited
Outside Japan: Transportation ton-kilometer x Emissions per unit
  • CO2 emissions related to domestic transportation by Fujitsu Frontech Limited, based on the Act on the Rationalizing Use of Energy and Shifting to Non-fossil Energy. The fuel economy method (for some vehicle) or the improved ton-kilometer method (vehicle, trail, air).
  • GHG Protocol emissions coefficient database (outside Japan)
05Waste generated in operationsMain 5 SitesAnnual amounts of waste (discharged mainly by business sites owned by Fujitsu Frontech Group) processed or recycled by type and processing method x Emission per unit of annual amounts of waste processed or recycledDatabase of emissions unit values published by Ministry of the Environment and Ministry of Economy, Trade and Industry
06Business travelIn Japan(By means of transportation) Σ (Transportation expense payment x Emission per unit)
  • Basic Guidelines on Accounting for Greenhouse Gas Emissions Throughout the Supply Chain published by Ministry of the Environment and Ministry of Economy, Trade and Industry
  • Database of emissions unit values published by them
07Employee commutingIn Japan(By means of transportation) Σ (Transportation expense payment x Emission per unit)
  • Basic Guidelines on Accounting for Greenhouse Gas Emissions Throughout the Supply Chain published by Ministry of the Environment and Ministry of Economy, Trade and Industry
  • Database of emissions unit values published by them
08Leased assets (Upstream)GlobalAnnual amounts of fuel oil and gas, electricity and heat consumed mainly at leased business sites x Emissions per unit of fuel oil and gas, electricity and heat consumed
  • Act on Promotion of Global Warming Countermeasures - GHG Emissions Accounting, Reporting and Disclosure System
  • IEA CO2 Emissions from Fuel Combustion Highlights (outside Japan)
09Transportation and distribution (Downstream)N/AN/AN/A
10Processing of sold products---
11Use of sold productsGlobalElectricity consumption during product use x emissions per unit of electricity
  • The Electric Power Council for a Low Carbon Society (In Japan)
  • Latest IEA value (Outside Japan)
12End-of-life treatment of sold productsGlobalΣ {Tonnage of each products sold during the fiscal year x rate by type of waste and processing method x Emissions unit value for the type of waste and processing method (tCO2e/t)}Database of emissions unit values published by Ministry of the Environment and Ministry of Economy, Trade and Industry
13Leased assets (Downstream)N/AN/AN/A
14FranchisesN/AN/AN/A
15InvestmentN/AN/AN/A
  • *3:
    3 Sites in Japan (Headquarters / Tokyo Plant, Niigata Plant, Kumagaya SSC) and 2 Sites outside Japan (FDTP, FFNA)
Top of Page