Skip to main content

Archived content

NOTE: this is an archived page and the content is likely to be out of date.

Hardware VRS

VRS4.5 Professional PFU OEM Bundle for fi-5900C Update


Supported Scanner Models

  • fi-5900C

Download

VRS4.5 Professional PFU OEM Bundle Disk space
icon-download vrs45_4_5900patch.exe (size:921KB)
1.7Mbyte

Modifications

  • Page size detection performance for dark colored paper documents is improved in fi-5900C models using VRS4.5.

How to use

  • Refer to "README" (222 KB) file on how to apply the update module.

VRS4.5 Professional PFU OEM Bundle Patch


Supported Scanner Models

  • fi-5900C, fi-4860C2, fi-6770A, fi-6670A

Download

VRS4.5 Professional PFU OEM Bundle Disk space
icon-download vrs_4.5_pfucga_oem_bundle.exe (size:186MB)
300Mbyte

Modifications

  1. Advanced Clarity Capabilities Extended
    Two new capabilities are available when you select Advanced Clarity:
    • Analyze Color:
      For pages that contain a color background or color text, this option produces optimal black and white images by including subtle color content variations in the page evaluation. Otherwise, only grayscale variations are evaluated.
    • Ignore Pictures:
      Ignores pictures or photos when VRS evaluates the page content. As a result, the clarity improvements are applied to other (non-picture) content on the page.
  2. Improved Kofax VRS ISIS interface with extended VRS profile management options
  3. Improved Edge Cleanup
    When Edge Cleanup is active, VRS trims the same amount of pixels from the top, bottom, left, and right edges of an image to ensure that no imperfections remain after Auto Crop is performed.
  4. Support for the TWAIN 2.0 standard.
  5. Some problems in PFU VRS4.2 from an ISIS application are corrected.

How to use

  1. Begin by logging in as an "Administrator".
  2. Download "VRS4.5 Professional Patch" onto your computer's desktop and then proceed to activate it.
    (Make sure that VRS is not running when you do this.)
  3. For how to use VRS4.5 Professional Patch, please follow the "Readme". (260 KB)

Hardware VRS4.2 Professional Download

VRS4.2 Professional PFU OEM Bundle


Supported Scanner Models

  • fi-5900C, fi-4860C2

Download

VRS4.2 Professional PFU OEM Bundle Disk space
icon-download vrs_4.2_pfucga_oem_bundle.exe (size:175MB)
300Mbyte

Modifications

  1. Addition of VRS Desktop Productivity function
    • Scan to desktop
      - Scanning from the desktop and the context menu of the specified foler is enabled.
    • Scan to e-mail
      - The addition of VRS button to E-mail (Microsoft® Outlook 2003 / XP / 2007 or Lotus Notes 6.x) enables scanning and attaching the image without using another scanner application.
  2. Delete Blank Pages
    The function to delete the blank page when using Image Control application is supported.
  3. Addition of the supported file formats
    The follwing file formats to save are newly supported.
    • .png, .gif, .dcx, .lzw
  4. Improvement on TWAIN application
    UI when using TWAIN application is modified in order to improve the usability.
  5. Windows Vista™ 64bit support
    Windows Vista™ 64bit is newly supported.

    Support OS:

    Windows Vista™ Business (64 bit)
    Windows Vista™ Enterprise (64 bit)

    * Desktop Productivity function cannot be used under the 64 bit environment.

How to use

  1. Begin by logging in as an "Administrator".
  2. Download "VRS4.2 Professional Patch" onto your computer's desktop and then proceed to activate it.
    (Make sure that VRS4.1 is not running when you do this.)
  3. An "Update" dialogue box will inform you when the "VRS4.2 Professional Patch" update has been completed.
  • For how to use VRS4.2 Professional Patch, please follow the "Readme". (308 KB)

Service Pack2 MF Patch

VRS4.1 PFU OEM Bundle Service Pack2 MF Patch

VRS4.1 PFU OEM Bundle Service Pack2 MF Patch

Since users are required to accept the terms declared in the software license agreement prior to downloading this software, please read "terms of the Software license agreement" (20 KB) beforehand.

[Download]

Modifications

The following errors have been modified.

  1. "Bad Image Width" error appears when the multifeed occurs with the first page of the document after the scanner power is on.
  2. "Compressor failed" error appears when the multifeed occurs with color or greyscale scanning while the blank page detect function is enabled.

How to use Service Pack2 MF Patch

  1. Begin by logging in as an "Administrator".
  2. Download "SP2 MF Patch (vrs410mfpatch.exe)" onto your computer's desktop and then proceed to activate it.
    (Make sure that VRS4.1 is not running when you do this.)
  3. An "Update" dialogue box will inform you when the "SP2 MF Patch" update has been completed.
  • For how to use Service Pack2 MF Patch, please follow the "Readme" (750 KB).

Service Pack2 MR Patch

VRS4.1 PFU OEM Bundle Service Pack2 MR Patch

VRS4.1 PFU OEM Bundle Service Pack2 MR Patch

Since users are required to accept the terms declared in the software license agreement prior to downloading this software, please read "terms of the Software license agreement" (74 KB) beforehand.

[Download]

Modifications

  1. SOP and VRS can co-exist
    When using VRS, both SOP and VRS are enabled.
  2. Faster Auto Orientation
    Auto Orientation when using VRS is sped up.
  3. Background Color Suppression for AutoColorDetection support
    In Auto Color Detection, documents with a single background color are processed as monochrome.

How to use Service Pack 2 MR Patch

  1. Begin by logging in as an "Administrator".
  2. Download "SP2 MR Patch (vrs_4.1_sp2mr_pfu_oem_4860_5900.exe)" onto your computer's desktop and then proceed to activate it.
    (Make sure that VRS4.1 is not running when you do this.)
  3. An "Update" dialogue box will inform you when the "SP2 MR Patch" update has been completed.
  • For how to use Service Pack2 MR Patch, please follow the "Readme" (251 KB).

Service Pack2 Patch download

VRS4.1 PFU OEM Bundle Service Pack2 Patch download


Supported Scanner Models

  • fi-5900C, fi-4860C2

OS

  • Microsoft® Windows® 2000 Professional
  • Microsoft® Windows® XP Professional (32 bit)
  • Microsoft® Windows Vista™ Business (32 bit)
  • Microsoft® Windows Vista™ Enterprise (32 bit)

Before Downloading - Software License Agreement Required

Since users are required to accept the terms declared in the software license agreement prior to downloading this software, please read "terms of the Software license agreement" (74 KB) beforehand.

Service Pack2 Patch Version 1.00.000 Disk space
[Download] PFUPROOEMUpdate.exe (size: 1.11MB)
10Mbyte


Modifications

The following errors are modified.

  1. In Windows Vista, if the user selects the scanner source in an application where VRS is used via ISIS (e.g. ScandAll PRO), it displays a message which indicates that all Windows applications are closing.
  2. Its performance with Auto Page Orientation enabled becomes slow compared to versions prior to SP2, depending on the contents of the documents or the direction that the documents are fed in.

How to use Service Pack2 Patch

  1. Begin by logging in as an "Administrator".
  2. Download "SP2 Patch" onto your computer's desktop and then proceed to activate it.
    (Make sure that VRS4.1 is not running when you do this.)
  3. An "Update" dialogue box will inform you when the "SP2 Patch" update has been completed.

Service Pack2 and Installation Guide download

VRS4.1 PFU OEM Bundle Service Pack2 and Installation Guide download

VRS4.1 PFU OEM Bundle Service Pack2

Since users are required to accept the terms declared in the software license agreement prior to downloading this software, please read "terms of the Software license agreement" (74 KB) beforehand.

[Download]

  • Installation Guide   icon-download English (752 KB) (753KB)
  • Installation Guide   icon-download Japanese (1.06 MB ) (1.089KB)
  • Installation Guide   icon-download German (997 KB) (997KB)
  • Installation Guide   icon-download French (986 KB) (987KB)
  • Installation Guide   icon-download Italian (958 KB) (958KB)
  • Installation Guide   icon-download Spanish (972 KB) (972KB)
  • Installation Guide   icon-download Korean (1.33 MB ) (1,358KB)
  • Installation Guide   icon-download Chinese(Traditional) (1.10 MB ) (1,131KB)
  • Installation Guide   icon-download Chinese(Simplified) (954 KB) (954KB)

Modifications

  1. Windows Vista™ support
    Supported OS: Windows Vista™ Business (32bit) / Windows Vista™ Enterprise (32bit)
  2. Punched hole removal
    Detects and removes punched hole marks from scanned images.

How to use Service Pack2

  1. Begin by logging in as an "Administrator".
  2. Download "SP2 (vrs_4.1_sp2_pfu_oem_4860_5900.exe)" onto your computer's desktop and then proceed to activate it.
    (Make sure that VRS4.1 is not running when you do this.)
  3. An "Update" dialogue box will inform you when the "SP2" update has been completed.
  • For how to use Service Pack2 Patch, please follow the "Readme" (224 KB).