Specifications | Configuration |
MBA3 NC Series Catalog
FEATURES
- High-speed access, 15,000rpm.
- Large capacity of up to 300GB.
- Ultra-4 (U320) interface supports the high transfer speed up to 320MB/sec
- Suitable for mission critical servers and storage arrays.
Specifications
FUNCTIONAL SPECIFICATIONS
| Disks | MBA3073NC | 1 | |
|---|---|---|---|
| MBA3147NC | 2 | ||
| MBA3300NC | 4 | ||
| Heads | MBA3073NC | 2 | |
| MBA3147NC | 4 | ||
| MBA3300NC | 8 | ||
| Rotational Speed | 15,000min-1 (15,000rpm) | ||
| Average Latency Time | 2.0ms (typical) | ||
| Seek Time | Minimum | Read 0.2ms (typical), Write 0.4ms (typical) | |
| Average | Read 3.4ms (typical), Write 3.9ms (typical) | ||
| Maximum | Read 8.0ms (typical), Write 9.0ms (typical) | ||
| Physical Dimensions |
Width | 101.6mm | |
| Depth | 147.0mm (maximum) | ||
| Height | 26.1mm (maximum) | ||
| Weight | 0.8kg (maximum) | ||
| Interface | Ultra 320 SCSI 80pin | ||
| Power Consumption |
Idle | 13.06W (typical) | |
| Energy Efficiency (2) | MBA3073NC | 0.178W/GB (d Rank) | |
| MBA3147NC | 0.089W/GB (e Rank) | ||
| MBA3300NC | 0.044W/GB (f Rank) | ||
| Data Transfer Rate | 320MB/s (maximum) [Ultra 320] | ||
Buffer size (3) |
8MB |
||
| Acoustic Noise (4) | Idle | 3.6Bels (typical) | |
ENVIRONMENTAL SPECIFICATIONS
| Ambient Temperature(5) |
Operating | 5ºC to 55ºC (ambient) 5ºC to 60ºC (disk enclosure surface) |
|---|---|---|
| Non-operating | -40ºC to 70ºC | |
| Gradient | 20ºC/h or less | |
| Relative Humidity |
Operating | 5% to 95% RH (no condensation) |
| Non-operating | 5% to 95% RH (no condensation) | |
| Maximum wet bulb | 29ºC | |
| Vibration | Operating | 0.6mm [5Hz to 20Hz] 9.8m/s2 (1G) [20Hz to 300Hz] or less |
| Non-operating | 3.1mm [5Hz to 20Hz] 49m/s2 (5G) [20Hz to 300Hz] or less |
|
| Shock | Operating | 637.4m/s2 (65G) [2ms duration] |
| Non-operating | 2,451.7m/s2 (250G) [2ms duration] | |
| Power requirements |
+5V±5%, +12V±5% |
|
Specifications are subject to change without notice.
- 1 GB:
- One gigabyte (GB) = one billion bytes; accessible capacity will be less and actual capacity depends on the operating environment
and formatting.
The formatted capacity is an estimate for 512 bytes per sector. - 2 Rank:
- Energy efficiency based on the Law Concerning the Rational Use of Energy indicates the value obtained by dividing power consumption by the storage capacity (Japan only).
- 3 MB:
- One megabyte (MB) as 1,048,576 bytes for Hard Disk Drives' cache size.
Small portion of buffer memory is used for drive firmware control. - 4 Bels:
- A unit for indicating noise levels. 1 Bels is equivalent to 10 decibels.
- 5 ºC:
- degree C.