Replacing the Consumables

Replace the consumables in the following procedure:


ATTENTION: Always reset each sheet counter after replacing consumables.
For details about resetting the counters, refer to (3) at the end of this page.

(1) Replacing the Brake Roller

  1. Remove all documents from the ADF paper chute (feeder).
  2. Pull the ADF release tab towards you to open the ADF.

    scanning

    a ADF Release Tab

    scanning CAUTION: Be careful not to have your fingers caught when the ADF closes.

  3. Remove the brake roller.
    1. Hold both ends of the brake roller cover, and open it in the direction of the arrow.

      scanning

    2. Lift the brake roller to disengage the right side of the shaft, then pull out the shaft from the slot on the left.

      scanning

  4. Remove the brake rollers from the shaft.

    scanning

  5. Attach a new brake roller on the shaft.
    Insert the protrusion on the shaft into the slot.

    scanning

    a Protrusion
    b Slot

     

  6. Attach the brake roller.
    1. Fit the left end of the shaft in the slot then attach the right side.

      scanning

    2. Close the brake roller cover.
      ATTENTION: Confirm that the brake roller is installed properly. Otherwise, it may cause feeding errors such as paper jams.

  7. Close the ADF.

    scanning CAUTION: Be careful not to have your fingers caught when closing the ADF.

  8. Reset the brake roller counter. Refer to (3).

(2) Replacing the Pick Roller

  1. Remove all documents from the ADF paper chute (feeder).
  2. Remove the ADF paper chute (feeder).
    Hold both ends of the ADF paper chute (feeder). Lift the chute in the direction of the arrow ①, then pull it in the direction of the arrow ②.

    scanning

  3. Pull the ADF release tab towards you to open the ADF.

    scanning

    a ADF Release Tab

    scanning CAUTION: Be careful not to have your fingers caught when the ADF closes.

  4. Remove the pick roller.
    1. Open the sheet guide by lifting the tab.

      scanning


       

    2. Rotate the bushing on the pick roller in the direction of the arrow.

      scanning


      a Bushing

       

    3. Slightly lift the bushing on the pick roller in the direction of the arrow ① (about 5 mm) first. Pull the shaft end of the pick roller out of the slot in the direction of the arrow ② and then lift the pick roller in the direction of the arrow ③.

      scanning



      ATTENTION: Be careful not to touch the gear near the bushing on the pick roller because it has grease over it.

  5. Remove the pick rollers (× 2) one by one from the shaft.
    1. Pull out the pick roller from the shaft as you lift the retaining clip.

      scaning


      a Retaining Clip
      b Shaft
      c Pick Roller

       

    2. Pull out the other pick roller from the shaft as you lift the retaining clip.

      scanning


      a Retaining Clip
      b Shaft
      c Pick Roller

       

  6. Attach new pick rollers (× 2) on the shaft one by one.
    1. Insert the retaining clip on the pick roller in the slot on the shaft.

      scanning


      a Retaining Clip
      b Slot
      c Shaft
      d Pick Roller

       

    2. Insert the retaining clip on the other pick roller into the slot on the shaft.

      scanning


      a Retaining Clip
      b Slot
      c Shaft
      d Pick Roller

       


    ATTENTION: Confirm that the pick roller is installed properly. Otherwise, it may cause feeding errors such as paper jams.
    Make sure you insert the pick roller until they lock in place.

  7. Attach the pick roller.
    1. Insert the left end of the shaft into the slot at an angle, and the rest of the shaft gradually as you lower the other end.

      scanning

    2. Rotate the bushing on the pick roller in the direction of the arrow.

      scanning


      a Bushing

       

    3. Close the sheet guide. Make sure that both ends of the sheet guide are locked firmly.

      ATTENTION: Confirm that the pick roller is installed properly. Otherwise, it may cause feeding errors such as paper jams.

  8. Close the ADF.

    scanning CAUTION: Be careful not to have your fingers caught when closing the ADF.

  9. Attach the ADF paper chute (feeder).
    Insert the tabs on the ADF paper chute (feeder) in the slots on the back of the scanner in the direction of the arrow ①. Then, lower the chute in the direction of the arrow ② to fix it in position.
    Make sure that the surface with the side guides is facing up.

    scanning



    ATTENTION: Attach the ADF paper chute (feeder) so that there is no gap from the scanner.

  10. Reset the pick roller counter. Refer to (3).

(3) Resetting the Sheet Counter

  1. Confirm that the scanner is connected to the computer, then turn on the scanner.
  2. Open the [Software Operation Panel] window.
    • Windows Vista/Windows Server 2008/Windows 7
      Select [Start] menu [All Programs] [fi Series] [Software Operation Panel].
    • Windows Server 2012/Windows 8
      Right-click the Start screen, and select [All apps] on the app bar [Software Operation Panel] under [fi Series].
    • Windows Server 2012 R2/Windows 8.1
      Click [↓] on the lower left side of the Start screen and select [Software Operation Panel] under [fi Series].
      To display [↓], move the mouse cursor.
    • Windows 10
      Select [Start] menu [All apps] [fi Series] [Software Operation Panel].
  3. From the listing on the left, select [Device Setting].

    scanning

  4. Click the [Clear] button for the replaced consumable.
    The counter is reset to "0".
  5. Click the [OK] button on the [Software Operation Panel] window.
    A message window appears.
  6. Click the [OK] button.
    The settings are saved.