Replacing the Consumables

Replace the consumables in the following procedure.


Win CAUTION:
Make sure to reset the sheet counter after replacing the consumables.
For details, refer to (3) at the end of this page.


(1) Replacing the Brake Roller

  1. Remove all documents from the ADF paper chute (Feeder).
  2. Pull the ADF release tab towards you to open the ADF.

    Win CAUTION:
    Be careful not to have your fingers caught when the ADF closes.

  3. Remove the brake rollers.
    • ⅰ. Hold both ends of the cover, and open it in the direction of the arrow.

      Win
       
    • ⅱ. Lift the right side of the roller first, then pull out the shaft from the slot on the left.

      Win
       
  4. Remove the brake rollers from their shaft.

    Win
     
  5. Attach new brake rollers on the shaft.
    Insert the protrusion on the shaft into the slot.

    Win


    a Protrusion
    b Slot

  6. Attach the shaft.
    • ⅰ. Insert the left end of the shaft into the hole in accordance with the hole shape, and then attach the right side of the shaft.

      Win
       
    • ⅱ. Close the cover.

      Win CAUTION:
      Confirm that the brake rollers are installed properly.
      Otherwise, it may cause feeding errors such as paper jams.

  7. Attach the shaft.

    Win CAUTION:
    Be careful not to have your fingers caught when the ADF closes.


    The procedure can be viewed on the icon-movieVideo.
  8. Reset the brake roller counter. Refer to (3)

(2) Replacing the Pick Roller

  1. Remove all documents from the ADF paper chute (Feeder).
  2. Hold both ends of the ADF paper chute (Feeder), and lift ① then pull it out ② in the direction of the arrow.

    Win
     
  3. Pull the ADF release tab towards you to open the ADF.

    Win CAUTION:
    Be careful not to have your fingers caught when the ADF closes.

  4. Remove the pick rollers.
    • ⅰ. Open the sheet guide by lifting the tab.

      Win
       
    • ⅱ. Rotate the bushing on the shaft.

      Win

      a Bushing

    • ⅲ. Lift the bushing in the direction of the arrow ① (about 5 mm) first, then pull the end of the shaft out of the slot in the direction of the arrow ②, and finally pull out the shaft completely in the direction of the arrow ③.

      Win


      Win CAUTION:
      Be careful not to touch the gear near the bushing on the shaft because it contains grease.

  5. Remove the pick rollers (×2) one by one from the shaft.
    • ⅰ. Pull out the pick roller from the shaft as you lift the retaining clip.

      Win

      a Retaining clip
      b Shaft
      c Pick roller

    • ⅱ. Pull out the other pick roller from the shaft as you lift the retaining clip.

      Win

      a Retaining clip
      b Shaft
      c Pick roller

  6. Attach a new pick roller on the shaft one by one.
    • ⅰ. Insert the retaining clip of the pick roller into the slot.

      Win

      a Retaining clip
      b Slot
      c Shaft
      d Pick roller

    • ⅱ. Insert the retaining clip of the other pick roller into the slot.

      Win

      a Retaining clip
      b Slot
      c Shaft
      d Pick roller


      Win CAUTION:
      Confirm that the pick rollers are installed properly.
      Otherwise, it may cause feeding errors such as paper jams.
      Make sure to insert the pick rollers until they lock in place.

  7. Attach the shaft.
    • ⅰ. Insert the left end of the shaft into the slot, and lower the other end gradually.

      Win

    • ⅱ. Rotate the bushing to lock the shaft.

      Win

      a Bushing

    • ⅲ. Close the sheet guide. Make sure that both ends of the sheet guide are locked firmly.

      Win CAUTION:
      Confirm that the pick rollers are installed properly.
      Otherwise, it may cause feeding errors such as paper jams.

  8. Close the ADF.

    Win CAUTION:
    Be careful not to have your fingers caught when the ADF closes.

  9. Attach the ADF paper chute (Feeder).
    Insert the tabs into the slots on the back of the scanner in the direction of the arrow ①, and tilt the ADF paper chute (Feeder) in the direction of the arrow ② until it locks in place.
    Make sure that the surface with the side guides is facing up.

    Win

    The procedure can be viewed on the icon-movieVideo.
  10. Reset the pick roller counter. Refer to (3).

(3) Resetting the Sheet Counter

  1. Confirm that the scanner is connected to the computer, then turn on the scanner.
  2. Open the [Software Operation Panel] window.
    • Windows® XP/Windows Vista®/Windows Server® 2008/Windows® 7
        Select [Start] menu → [All Programs] → [fi Series] → [Software Operation Panel]
    • Windows Server® 2012/Windows® 8
        Right-click the Start screen, and select [All apps] on the app bar → [fi Series] → [Software Operation Panel].
    • Windows Server® 2012 R2/Windows® 8.1
        Select [↓] on the lower left side of the Start screen → [Software Operation Panel] under [fi Series].
        To display [↓], move the mouse cursor.
  3. From the listing on the left, select [Device Setting].

    Win
     
  4. Click the [Clear] button for the consumable that you replaced.
      → The counter is reset to "0".
  5. Click the [OK] button on the [Software Operation Panel] dialog box.
      → A message appears.
  6. Click the [OK] button.
      → The settings are saved.
Top of Page