Replacing the Print Cartridge

Follow the instructions below to replace the print cartridge.

For Post-Imprinter (click here) For Pre-Imprinter
  1. Turn off the scanner.
  2. Hold the blue part located on the center of the Hopper.
    Scanning
  3. Flip down the Hopper gently.
    Scanning
  4. Open the Imprinter Cover.
    Scanning
  5. Move the Print Cartridge Holder to where the cartridge can be removed easily.
    Scanning
  6. Turn the blue lever toward the left and open the Print Cartridge Holder.
  7. Take the print cartridge out from the holder.
  8. Take a new print cartridge out of its pouch and detach the protection tape from the print cartridge.
  9. Insert the print cartridge.
    Scanning
  10. Turn the lever on the print cartridge toward the right to mount it.
    Scanning
  11. Close the Imprinter Cover.

    Reset the Ink Remain Counter. (Refer to the last section of this page.)

For Post-Imprinter
  1. Confirm the scanner is turned off.
  2. Press the tabs on the left and right sides of the Top Cover and lift to open the Top Cover.
    Scanning
  3. Turn the blue lever toward left and open the Print Cartridge Holder.
    Scanning
  4. Remove the print cartridge from the holder.
    Scanning
  5. Take a new print cartridge out of its pouch and detach the protection tape from the print cartridge.
  6. Turn the lever on the print cartridge toward right to mount it.
    Scanning
  7. Close the top cover and press lightly until it is fixed with the tabs.
    Scanning

    Reset the Ink Remain Counter as follows.

Reset the Remaining Ink Counter
  1. Confirm the scanner is connected to the PC before turning on the scanner.
  2. On the [Start] menu, select [Programs]-[Scanner Utility for Microsoft Windows]-[Software Operation Panel].
    CAUTION: If the [Software Operation Panel] is password protected, enter the password to cancel the View Only mode. For details on how to enter the password to cancel the View Only mode, refer to the fi-5950 Operator's Guide "8.1 Scanner Settings".

  3. Select the [Device Setting] tab.
    The following screen appears.

    Scaning

  4. Click the [Clear] button beside the Remaining Ink Counter for the replaced print cartridge, and then click the [OK] button. Click the [OK] button again on the message that appears.
    The Remaining Ink Counter will reset to 100%.