Data Sheets

Brocade VDX 6730 data sheet (141 KB)

Brocade VDX 6730

Revolutionizing the Way Data Center Networks Are Built

The Brocade VDX 6730 is a 10 Gigabit Ethernet (GbE) fixed port switch with LAN and native Fibre Channel ports. It supports multiple connectivity options, including classic Top-of-Rack (ToR) server deployments, Ethernet fabrics, and Ethernet storage connectivity for Fibre Channel over Ethernet (FCoE), iSCSI, NAS, and bridging Fibre Channel Storage Area Networks (SANs) and Ethernet fabrics.

Brocade VDX 6730

Feature overview

  Brocade VDX 6730-32 Brocade VDX 6730-76
Switching bandwidth (data rate, full duplex) 480 Gbps for Ethernet ports 1200 Gbps for Ethernet ports
Fibre Channel ports Eight 8 Gbps ports Sixteen 8 Gbps ports
Port-to-port latency 600 nanoseconds within 10-port group 600 nanoseconds within 10-port group
Form factor 1U 2U
Dimensions and weight Width: 42.8 cm (16.9 in.)
Height: 4.37 cm (1.7 in.)
Depth: 38.4 cm (15.1 in.)
Weight: 7.3 kg (16.3 lb)
Width: 43.0 cm (17.0 in.)
Height: 8.7 cm (3.5 in.)
Depth: 43.2 cm (17.0 in.)
Weight: 15.3 kg (33.9 lb)
1/10 GbE SFP+ ports 24 60
Ports on Demand (PoD) increments 16, 24 40, 50, 60
Power supplies Two hot-swappable, load-sharing Two hot-swappable, load-sharing
Cooling fans N+1 redundant, integrated into power supplies Three independent fans in a N+1 redundant configuration

Scalability Information (*Note 1)

Connector options 1 GbE copper SFP option
1000Base-SX and 1000Base-LX
10 Gbps SFP+ options: 1/3/5 m direct-attached copper (Twinax)
10 GbE SR and 10 GbE LR
8 Gbps Fibre Channel optics: 8 Gbps Fibre Channel SWL, 8 Gbps Fibre Channel LWL 10 km, 8 Gbps Fibre Channel ELWL 25 km
Out-of-band Ethernet management: RJ-45 (fixed)
Remote lights-out management: 10/100/1000 BaseT Ethernet
Console Management: RJ45 to RS-232 (fixed)
Firmware and diagnostic: USB
Maximum VLANs 4,096
Maximum MAC addresses 32,000
Maximum port profiles (AMPP) 256
Maximum Layer 2 multicast groups 2,000
Maximum Spanning Tree instances 32
Maximum per-port priority pause level 8
Maximum LAG groups 512
Maximum members in a standard LAG 16
Maximum MAC addresses in a VCS fabric 30,000
Maximum switches in a VCS fabric 24
Maximum ECMP paths in a VCS fabric 8
Maximum trunk members for VCS fabric ports 8
Maximum switches across which a vLAG can span 4
Maximum members in a vLAG 32
Maximum jumbo frame size 9,208 bytes
Queues per port 8
DCB Priority Flow Control (PFC) classes 8
Maximum Layer 2 ACLs 1,000
Maximum ARP entries 12,000
Maximum IPv4 routes 2,000
Operating system Brocade Network OS
Layer 2 switching features - MAC Learning and Aging
- Static MAC Configuration
- Link Aggregation Control Protocol (LACP) IEEE 802.3ad/802.1AX
- Virtual Local Area Networks (VLANs)
- VLAN Encapsulation IEEE 802.1Q
- Rapid Spanning Tree Protocol (RSTP) IEEE 802.1w
- Multiple Spanning Tree Protocol (MSTP) IEEE 802.1s
- STP IEEE 802.1D
- Per-VLAN Spanning Tree (PVST+/PVRST+)
- STP PortFast and PortFast BDPU Guard
- STP Root Guard
- Layer 2 Access Control Lists (ACLs)
- IGMP v1/v2 Snooping
- Pause Frames IEEE 802.3x
Brocade VCS features - Automatic Fabric Formation
- Distributed Fabric Services
- Transparent LAN Services
- Virtual Link Aggregation Group (vLAG) spanning multiple physical switches
- Switch Beaconing
- Distributed Configuration Management
- Transparent Interconnection of Lots of Links (TRILL)
- Equal Cost Multi-Path (ECMP)
- Automatic Migration of Port Profiles (AMPP)
- VM-aware network automation
DCB features - Priority-based Flow Control (PFC) IEEE 802.1Qbb
- Enhanced Transmission Selection (ETS) IEEE 802.1Qaz
- Data Center Bridging eXchange (DCBX)
- DCBX Application Type-Length-Value (TLV) for FCoE and iSCSI
FCoE features - Multihop Fibre Channel over Ethernet (FCoE); requires Brocade VCS technology
- FC-BB5 compliant Fibre Channel Forwarder (FCF)
- Native FCoE forwarding
- End-to-end FCoE (initiator to target)
- FCoE Initialization Protocol (FIP) v1 support for FCoE devices login and initialization
- Fibre Channel over Ethernet (FCoE)
- Name Server-based zoning
- Supports connectivity to FIP Snooping Bridge (FSB) device
Fibre Channel features - Name Server-based zoning
- FC authentication
- Bridging to Fibre Channel SANs
Quality of Service (QoS) - Eight priority levels for QoS
- Class of Service (CoS) IEEE 802.1p
- DSCP Trust
- DSCP to Traffic Class Mutation
- Random Early Discard
- Per-port QoS configuration
- Scheduling: Strict Priority (SP), Shaped Deficit Weighted Round-Robin (SDWRR)
Switch health monitoring - Fabric Watch monitoring and notification

*Note 1: Please refer to the latest version of the release notes for the most up-to-date scalability numbers

Management

Management and control - IPv4/IPv6 management
- Industry-standard Command Line Interface (CLI)
- Remote lights out management (future update)
- In-band management
- Link Layer Discovery Protocol (LLDP) IEEE 802.1AB
- MIB II RFC 1213 MIB
- Switch Beaconing
- Switched Port Analyzer (SPAN)
- Telnet
- SNMP v1/v2C,v3
- sFlow RFC 3176
- Out of Band management (standalone mode)
- RMON-1, RMON-2
- NTP
- Management Access Control Lists (ACLs)
- Role-Based Access Control (RBAC)
Security - Port-based Network Access Control IEEE 802.1X
- RADIUS
- TACACS+
- Secure Shell (SSHv2)
- BPDU Guard
- Lightweight Directory Access Protocol (LDAP)
- Secure Control Protocol

Mechanical

Enclosure
Brocade VDX 6730-32
Front-to-rear airflow; power from back
Rear-to-front airflow; power from back
1U
System weight: 16.3 lb with two power supply FRUs, without transceivers
Enclosure
Brocade VDX 6730-76
Front-to-rear airflow; power from back
Rear-to-front airflow; power from back
2U
System weight: 33.9 lb with two power supply FRUs, without transceivers

Environmental

Temperature Operating: 0°C to 40°C (32°F to 104°F)
Non-operating and storage: −25°C to 70°C (−13°F to 158°F)
Humidity Operating: 10% to 85% non-condensing
Non-operating and storage: 10% to 90% non-condensing
Altitude Operating: Up to 3000 meters (9842 feet)
Non-operating and storage: Up to 12 kilometers (39,370 feet)
Shock Operating: 20 g, 6 ms half-sine
Non-operating and storage: Half-sine, 33 g 11 ms, 3/eg Axis
Vibration Operating: 0.5 g sine, 0.4 grms random, 5 to 500 Hz
Non-operating and storage: 2.0 g sine, 1.1 grms random, 5 to 500 Hz
Airflow
Brocade VDX 6730-32
Maximum: 53 CFM
Nominal: 35 CFM
Heat dissipation 447 BTU/hr
Airflow
Brocade VDX 6730-76
Maximum: 115 CFM
Nominal: 76 CFM
Heat dissipation 477 BTU/hr (for 32-port switch); 1194 BTU/hr (for 76-port switch)

Power

Power supplies Two internal, redundant, field-replaceable, load-sharing AC power supplies
Power inlet C13
Input voltage 100 V to 240 V ~5 A - 2.5 A
Input line frequency 47 to 63 Hz
Inrush current 50 amps max
Maximum current 4 amps max (24-port switch); 7 amps max (60-port switch)
Maximum power consumption
Brocade VDX 6730-32
140 W
Maximum power consumption
Brocade VDX 6730-76
350 W

Safety Compliance

- Bi-Nat UL/CSA 60950-1 Second Edition
- CAN/CSA-C22.2 No. 60950-1 Second Edition
- EN 60950-1 Second Edition
- IEC 60950-1 Second Edition
- GB4943-2001 and GB9254-1998
- CNS 14336(94)

EMC

- FCC Class A
- ICES A
- VCCI-A
- CE
- C
- BSMI
- GOST
- KC Class A
- CCC

Immunity

- ANSI C63.4
- ICES-003 Class A
- CISPR22 and JEIDA (Harmonics)
- EN55022 and EN55024
- EN55022 or CISPR22 or AS/NZS CISPR22
- CNS 13438(95)
- 51318.22-99 and 51318.24-99
- KN22 and KN24
- GB17625.1-2003

Environmental Regulatory Compliance

- RoHS-6 (with lead exemption) Directive 2002/95/EC

Standards Compliance

Brocade VDX 6730 products conform to the following Ethernet standards:
- IEEE 802.1D Spanning Tree Protocol
- IEEE 802.1s Multiple Spanning Tree
- IEEE 802.1w Rapid reconfiguration of Spanning Tree Protocol
- IEEE 802.3ad Link Aggregation with LACP
- IEEE 802.3ae 10G Ethernet
- IEEE 802.1Q VLAN Tagging
- IEEE 802.1p Class of Service Prioritization and Tagging
- IEEE 802.1v VLAN Classification by Protocol and Port
- IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
- IEEE 802.3x Flow Control (Pause Frames)
- IEEE 802.3ab 1000BASE-T
The following draft versions of the Data Center Bridging (DCB) and Fibre Channel over Ethernet (FCoE) standards are also supported on the
Brocade VDX 6730:
- IEEE 802.1Qbb Priority-based Flow Control
- IEEE 802.1Qaz Enhanced Transmission Selection
- IEEE 802.1 DCB Capability Exchange Protocol (Proposed under the DCB Task Group of IEEE 802.1 Working Group)
- FC-BB-5 FCoE (Rev 2.0)
- FC-BB-5 FCoE (Rev 2.0)