Climatic

Functional performance under requested climatic conditions to:

  • Find out if there is sufficient cooling of critical components (e.g. processor, transformer, choke coil).
  • Determine what happens to a product if enclosure openings are blocked.
  • Support the heat management system development process.

TESTING EQUIPMENT

  • Large climatic test cabinet (useable space: 5.1 m x 3.0 m x 2.8 m; door: 1.2 x 2.2 m; range: -40°C to +90°C)
  • Large temperature test cabinet (useable space: 4.7 m x 3.5 m x 2.4 m; door: 1.0 x 2.0 m; range: +5°C to +60°C)
  • Temperature/climatic chambers (useable space: 1.0 m x 1.5 m x 1.0 m; range: -40°C to +180°C)
  • Two-zone temperature shock cabinet (useable space: 0.77m x 0.61m x 0.57m; temperature range chamber 1 +50°C to +220°C and temperature range chamber 2 -75°C to +70°C within a 10 second change for test samples till 50 kg)

OVERVIEW OF OUR SERVICES

cold DIN-IEC-68-2-1 to -40°C
heat DIN-IEC-68-2-2 to +180°C
damp heat DIN-IEC-68-2-3 +10°C to +50°C
at relative humidity of
10% to 95%
damp heat (cycles) DIN-IEC-68-2-30
temperature change (slow) DIN-IEC-68-2-3
temperature change (fast) DIN-IEC-68-2-14