ETERNUS8000 model 900 Specifications
| RAID level | 0, 1, 1+0, 5, 6 | |||
|---|---|---|---|---|
| Storage capacity | For GlobalServer | With Fibre Channel disk drive | Physical capacity (*Note 1) | Max. 25.1TB |
| Logical capacity (*Note 2) | Max. 11.2TB | |||
| For UNIX/Industry Standard Server | With Fibre Channel disk drive | Physical capacity (*Note 1) | Max. 141.8TB | |
| Logical capacity (*Note 3) | Max. 110.3TB | |||
| With Nearline SATA disk drive | Physical capacity (*Note 1) | Max. 354.2TB | ||
| Logical capacity (*Note 3) | Max. 277.3TB | |||
| Number of controllers | Max. 4 | |||
| Host interface | Fibre Channel (Max. 4Gbit/sec), iSCSI (Max. 1Gbit/sec), OCLINK (Max. 17MB/sec), FCLINK (*Note 4) (Max. 2Gbit/sec) | |||
| Number of host interfaces | FC | 4 to 64 | ||
| iSCSI | 4 to 32 | |||
| OCLINK | 4 to 32 | |||
| FCLINK | 4 to 32 | |||
| Cache capacity | Max. 64GB | |||
| Number of drives | Max. 480 | |||
| Disk drive | Fibre Channel disk drive | Drive capacity | 300GB (10,000rpm) 300GB/146GB/73GB (15,000rpm) |
|
| Drive interface | Fibre Channel (Max. 4Gbit/sec) | |||
| Nearline SATA disk drive | Drive capacity | 750GB/500GB (7,200rpm) | ||
| Drive interface | Fibre Channel (Max. 4Gbit/sec) | |||
| Dimensions (W x D x H) | 740 x 995 x 1,800mm (Max. 1,980 x 995 x 1,800mm) |
|||
| Weight | Max. 2,220kg | |||
| Power requirements |
Voltage | 200 to 240VAC | ||
| Phase | Single phase | |||
| Frequency | 50 or 60Hz | |||
| Power consumption | Max. 16,100W | |||
| Heat dissipation | Max. 58,800kJ/h | |||
| Environmental conditions |
Temperature | 5 to 35°C (operating), 0 to 50°C (non operating) | ||
| Humidity | 20 to 80%RH (operating), 8 to 80%RH (non operating) | |||
*Note 1: Storage capacity is calculated as 1Kbyte = 1,000bytes, and includes system and hot space disks.
*Note 2: Storage capacity is calculated as formatted for GlobalServer.
*Note 3: The logical capacity value was calculated as 1 Kbytes = 1,024 bytes when formatted as RAID 1+0. User area capacity
differs depending on the environment.
*Note 4: The data transfer speed between the ETERNUS8000 and the FCLINK switch.