Fujitsu The Possibilities are Infinite

M263 S Series Jumper Setting

Obsolete product information

M2634S, M2635S, M2636S, M2637S

PCA Layout


All configurations marked * are default settings.


Set SCSI ID

JMP7 JMP6 JMP5 ID
OPEN OPEN OPEN 0
OPEN OPEN SHORT 1
OPEN SHORT OPEN 2
OPEN SHORT SHORT 3
SHORT OPEN OPEN 4
SHORT OPEN SHORT 5
SHORT SHORT OPEN 6
SHORT * SHORT * SHORT * 7

The drive is shipped from the factory with the SCSI ID set to 7.
This provides the drive with enough shorting straps for any ID. It must be remembered though that the host adapter normally takes ID 7 with all peripheral devices using IDs 0 - 6.

Other Functions

  • JMP4
    SHORT * Spin up at power on
    OPEN Spin via START/STOP UNIT command
  • JMP3
    SHORT * SCSI parity enabled
    OPEN SCSI parity disabled
  • JMP2
    SHORT * UNIT ATTENTION enabled
    OPEN UNIT ATTENTION disabled
  • JMP1
    SHORT * SCSI level: Common Command Set
    OPEN SCSI level: SCSI-2