M2617T, M2618T Jumper Setting
Obsolete product information

Location of setting Jumpers
1. Switch Settings
All configurations marked * are default settings.
1.1 Switch Settings (S/N: 00001 to 30000)
| Key SW1 | |||
| Alternation of IRQ 14/reserved | |||
| Key 1 | Key 2 | Key 5 | |
| OFF (*) | ON | OFF | Pin 29 = IRQ 14, Pin 31 = Reserved |
| OFF (*) | OFF (*) | ON (*) | Pin 29 = Reserved, Pin 31 = IRQ 14 |
| Key SW2 | |||
| Master drive/Slave drive | |||
| Key 1 | ON Slave drive | ||
| OFF (*) Master drive | |||
1.2 Switch settings (S/N: 30001 or larger)
| Key SW1 | |||
| Alternation of IRQ 14 / reserved | |||
| Key 1 | Key 2 | Key 5 | |
| OFF (*) | ON | OFF | Pin 29 = IRQ 14, Pin 31 = Reserved |
| OFF (*) | OFF (*) | OFF (*) | Pin 29 = Reserved, Pin 31 = IRQ 14 |
| Slave present (SLV) / active mode (ACT) | |||
| Key 3 | Key 4 | ||
| ON | OFF | Slave present mode | |
| OFF (*) | ON | Active mode | |
| Key SW2 | |||
| Master drive / Slave drive | |||
| Key 1 | ON Slave drive | ||
| OFF (*) Master drive | |||
2. Daisy chain connection
To a drive which does not meet ATA standard proposal, the M2617T and M2618T can be
connected as the master, the slave drive works under the following conditions:
Master: M2617T, M2618T
Slave: M2611, M2612, M2613, M2614, M2616, M2622, M2623 or M2624.
Note: Cable length should not exceed 30 centimeters.
| Slave drive | Master drive |
|---|---|
| M2617T / 18T | |
| M2611/2/3/4/6 | Slave present mode |
| M2622/3/4 | Active mode |