Fujitsu The Possibilities are Infinite

M2617T, M2618T Jumper Setting

Obsolete product information

  1. Switch Settings
    1.1 S/N: 00001 to 30000
    1.2 S/N: 30001 or larger
  2. Daisy chain connection

Location of setting Jumpers


1. Switch Settings

All configurations marked * are default settings.

1.1 Switch Settings (S/N: 00001 to 30000)

Key SW1
Alternation of IRQ 14/reserved
Key 1 Key 2 Key 5
OFF (*) ON OFF Pin 29 = IRQ 14, Pin 31 = Reserved
OFF (*) OFF (*) ON (*) Pin 29 = Reserved, Pin 31 = IRQ 14
Key SW2
Master drive/Slave drive
Key 1 ON Slave drive
OFF (*) Master drive

1.2 Switch settings (S/N: 30001 or larger)

Key SW1
Alternation of IRQ 14 / reserved
Key 1 Key 2 Key 5
OFF (*) ON OFF Pin 29 = IRQ 14, Pin 31 = Reserved
OFF (*) OFF (*) OFF (*) Pin 29 = Reserved, Pin 31 = IRQ 14
Slave present (SLV) / active mode (ACT)
Key 3 Key 4
ON OFF Slave present mode
OFF (*) ON Active mode
Key SW2
Master drive / Slave drive
Key 1 ON Slave drive
OFF (*) Master drive

2. Daisy chain connection

To a drive which does not meet ATA standard proposal, the M2617T and M2618T can be connected as the master, the slave drive works under the following conditions:
Master: M2617T, M2618T
Slave: M2611, M2612, M2613, M2614, M2616, M2622, M2623 or M2624.

Note: Cable length should not exceed 30 centimeters.

Slave drive Master drive
M2617T / 18T
M2611/2/3/4/6 Slave present mode
M2622/3/4 Active mode