Fujitsu The Possibilities are Infinite

M2266 Series Jumper Setting

Obsolete product information

M2266H, M2266S

  1. Terminal CN3/CN9
  2. Connector CN7
  3. Connector CNH1
  4. Terminal CNH2
  5. Terminal CNH3
  6. Terminal CNH4

PCA Layout

 M2266S PCA Layout
detailed image

Larger View

 M2266H PCA Layout
detailed image

Larger View


All configurations marked "*" are default settings.

With respect to the setting below;
- "short" means Jumper plug is set between specified pins.
- "open" means Jumper plug is removed from specified pins.



1. Terminal CN3, CN9

Same settings are assigned on the same pins of both CN3 and CN9.
Setting terminal: CN4, CN6, CN7, CN10

SCSI ID
ID 9-10 11-12 13-14
0 OPEN OPEN OPEN
1 OPEN OPEN SHORT
2 OPEN SHORT OPEN
3 OPEN SHORT SHORT
4 SHORT OPEN OPEN
5 SHORT OPEN SHORT
6 SHORT SHORT OPEN
7 * SHORT SHORT SHORT

Note:
The drive is shipped from the factory with the SCSI ID set to 7. But the links are offset, this is done intentionally as it will enable the user to configure the drive with enough shorting straps for any ID. It must be remembered though that the host adapter normally takes ID 7 with all peripheral devices using IDs 0 through to 6.

7-8 SHORT * Time monitoring is disabled
OPEN Time monitoring is enabled
5-6 SHORT * Read-Ahead caching is enabled
OPEN Read-Ahead caching is disabled
3-4 SHORT * reserved
1-2 SHORT * Normal operational mode
OPEN Diagnostic mode

2. Connector CN7

Factory use only.

3. Connector CNH1

LED display requirement
1-2 SHORT * LED active when drive connected to bus
OPEN LED active when drive READY
3-4 Factory use only.
5-6 Factory use only.
7-8 Factory use only.
9-10 Factory use only.
UNIT ATTENTION response
11-12 SHORT * CHECK CONDITION posted
OPEN CHECK CONDITION not posted
SCSI time monitoring
13-14 & 15-16 SHORT * CHECK CONDITION posted
SHORT * SHORT * Unlimited 250ms, 128 retries
SHORT OPEN 30 - 60 seconds 250ms, 10 retries
OPEN SHORT 30 - 60 seconds 250ms, unlimited retries
OPEN OPEN 1 - 2 seconds 1ms, 10 retries

4. Terminal CNH2

SCSI level
1-2 SHORT * SCSI-2
OPEN SCSI-1/CCS
Message mode
3-4 SHORT * SAVE DATA POINTER is issued for disconnection
OPEN SAVA DATA POINTER is not issued for disconnection after data transfer
Error report at MODE SELECT parameter rounding
5-6 SHORT * CHECK CONDITION status not posted
OPEN CHECK CONDITION status (REDCOVERED ERROR) posted
PER default value
7-8 SHORT * 0
OPEN 1
Motor start timing
9-10 SHORT * Motor start on power up
OPEN Motor start via START/STOP UNIT command
SCSI bus parity check
11-12 SHORT * Executed by IDD
OPEN Not executed by IDD
Synchronous mode transfer rate
13-14 SHORT * CHECK CONDITION status not posted
SHORT * 1.2 to 4.0MB/s
OPEN 1.2 to 2.67MB/s
15-16 SHORT * Enabled
OPEN Disabled

5. Terminal CN3

There are no user changeable settings on this terminal.

6. Terminal CNH4

SCSI Terminating Power
1-2 3-4 Function
SHORT * SHORT * Power is supplied to the terminating resistor from the IDD and TERMPWR pin. Power is also supplied to the TERMPWR pin from the IDD. (Pin 26 of the interface)
OPEN SHORT The TERMPWR pin is not used. Power is supplied to the IDD terminating resistor only from the IDD
SHORT OPEN Power is not supplied to the terminating resistor from the IDD, only from the TERMPWR pin.