Between absorbers:
17.6 m x 9.6 m x 6.2 m
HF power: 0.25 kW
Turntable: Ø 4m, load capacity 2.5 t, 360° rotating
Antenna height: 1 - 4m
Current of equipment under test:
max. 400 V / 63 A
Variable power via transformer
(max. 70 kVA, 100 - 500 V, 44 - 66 Hz)
Air pressure and water supply
Between absorbers:
7.3 m x 3.4 m x 3.3 m
HF power: 0.25 kW
Turntable: Ø 1.2m, 300 kg load capacity, 360° rotating
Current of equipment under test:
max. 400 V / 32 A
Usable space: 5.5 m x 3.5 m
Current of equipment under test: max. 400 V / 63 A
Variable power via transformer possible
Current of equipment under test: max. 400 V / 3 x 20 A